What this calculator does
A microstrip is a signal trace on the outer layer of a PCB, separated from a ground plane by a dielectric of height . Part of its field is in the dielectric and part is in the air above, so the wave travels with an effective permittivity between 1 and . That number sets both the characteristic impedance and the propagation delay.
This calculator gives you:
- the quasi-static impedance and (Hammerstad–Jensen), which is what most fabricators' impedance tables quote;
- the frequency-dependent and (Kirschning–Jansen), which matter above a few GHz, where more of the field moves into the substrate;
- conductor and dielectric loss per unit length, including copper roughness;
- the surface-wave onset frequency, above which a quasi-TEM model no longer applies.
Designing a 50 Ω trace
Click ⇄ Solve next to Trace width, choose Characteristic impedance at f as the target, and enter 50. The calculator inverts the model numerically and shows the width that gives exactly 50 Ω. You can solve for the substrate height or dielectric constant the same way, for example to back-calculate the effective from a measured impedance.
Worked example
Rogers RO4350B, mm (20 mil), , 1 oz copper (m), at 10 GHz. A 1.1 mm trace gives Ω with . That is a delay of about 143.5 ps/in, and the guided wavelength is about 17.7 mm. To hit exactly 50 Ω, use ⇄ Solve on the trace width: the answer is slightly narrower than 1.1 mm.
Accuracy and validity
| Model | Quantity | Stated accuracy | Range |
|---|---|---|---|
| Hammerstad–Jensen | , (static) | better than 0.2 % (vs. the original paper's reference) | , |
| Kirschning–Jansen | about 0.6 % | , , | |
| Jansen–Kirschning | about 2.5 % | same as above |
The calculator warns when your inputs fall outside these ranges. Real boards add effects that no closed-form model includes: solder mask (it lowers by roughly 1–3 Ω), trapezoidal etching, glass-weave variation, and that changes with frequency. For production stackups, confirm against your fabricator's field-solver result.
Loss
Conductor loss uses the surface resistance with a current-distribution factor and the Hammerstad roughness factor , where is the RMS surface roughness and the skin depth. This roughness model saturates at 2×. For very rough foils at mm-wave frequencies, the Huray model (coming to this site) is more accurate.