dBm, watts and volts
dBm is power relative to 1 milliwatt on a logarithmic scale: 0 dBm = 1 mW, +30 dBm = 1 W, −30 dBm = 1 µW. Each +10 dB multiplies the power by 10, and each +3 dB roughly doubles it.
To turn power into voltage you need the impedance of the load. In a 50 Ω system, 0 dBm is 224 mV RMS (632 mV peak-to-peak). In 75 Ω (video, CATV) it is 274 mV RMS.
dBµV and dBmV
EMC receivers and cable-TV equipment report voltage levels: dBµV is voltage relative to 1 µV, and dBmV relative to 1 mV. In a 50 Ω system the conversion is:
(more precisely ). In 75 Ω the offset is 108.75 dB.
Quick reference (50 Ω)
| dBm | Power | Vrms | Vpp |
|---|---|---|---|
| +30 | 1 W | 7.07 V | 20 V |
| +20 | 100 mW | 2.24 V | 6.32 V |
| +10 | 10 mW | 707 mV | 2.0 V |
| 0 | 1 mW | 224 mV | 632 mV |
| −30 | 1 µW | 7.07 mV | 20 mV |
| −60 | 1 nW | 224 µV | 632 µV |
All voltages assume a continuous sine wave. Modulated signals with a high peak-to-average ratio have peak voltages well above the CW values.