Skip to content
FiftyOhm
Esc
  • Air-core coilSingle-layer air-core solenoid inductance from Nagaoka's exact coefficient, compared with Wheeler's formula. Solve for the number of turns for a target inductance.Components & magnetics
  • Attenuator PadsResistor values for Pi, T, bridged-T and minimum-loss L-pad attenuators, with unequal impedances, power dissipation per resistor and E24/E96 rounding.Couplers, dividers & attenuators
  • CoaxCoax Z0, capacitance and inductance per length, velocity factor, loss, exact TE11 cutoff and breakdown voltage. Solve for D, d or εr from Z0.Transmission lines
  • CPW / GCPWCoplanar waveguide and grounded CPW impedance, effective permittivity, dispersion, delay and loss by conformal mapping. Solve for centre width or gap.Transmission lines
  • dBm ↔ W ↔ VConvert RF power between dBm, dBW, watts, Vrms, Vpeak, Vpp, dBµV and dBmV for any system impedance. Instant, accurate, with formulas.Fundamentals & conversions
  • Differential pairEdge-coupled microstrip and stripline differential impedance, Z0 even/odd, common-mode impedance, coupling and delay. Solve for spacing or width from Zdiff.Transmission lines
  • Filter OrderMinimum filter order to meet a passband/stopband attenuation mask for Butterworth, Chebyshev and elliptic responses, with the attenuation actually achieved.Filters
  • Free-space path lossFree-space path loss from the Friis equation, received power with antenna gains, and a far-field check. Solve for distance or frequency.Propagation & link budget
  • L / Pi / T MatchingDesign lumped L, Pi and T matching networks between complex source and load impedances. Both L solutions, loaded-Q Pi/T, component values and bandwidth.Matching & Smith chart
  • LC Filter DesignerDesign lumped LC ladder filters: Butterworth, Chebyshev or Bessel; low-pass, high-pass, band-pass, band-stop to order 10, with exact insertion loss and group delay.Filters
  • MicrostripMicrostrip Z0, effective permittivity, dispersion, delay and loss. Solve for trace width from target impedance. Hammerstad–Jensen + Kirschning–Jansen models.Transmission lines

Coaxial Cable Impedance Calculator

Coax Z0, capacitance and inductance per length, velocity factor, loss, exact TE11 cutoff and breakdown voltage. Solve for D, d or εr from Z0.

4 cited sources38 reference checksRuns in your browser

Inputs

Coaxial line cross-section: inner conductor diameter d inside an outer conductor of inner diameter DdDεrouter conductorinner conductor

Diameter of the dielectric, i.e. the inside of the shield.

Solid PTFE 2.02–2.1, solid PE 2.25–2.3, foam PE ≈ 1.4–1.6, air 1.0006.

Copper 58 MS/m, silver 62, aluminium 37.7. Silver-plated copper-clad steel behaves like silver at high frequency.

Field at which the dielectric breaks down. Dry air at sea level ≈ 3 kV/mm. Datasheet values for solid plastics (PTFE, PE: 20–60 kV/mm) are short-term thin-film figures; derate heavily.

Results

Characteristic impedance(Z₀)
48.862
Velocity factor(VF)
69.34%
TE₁₁ cutoff frequency(f_c,TE11)
34.886
Total loss(α)
10.921
Capacitance per length(C′)
98.456
Inductance per length(L′)
235.06
Propagation delay(τ)
122.19
Conductor loss(αc)
10.121
Dielectric loss(αd)
0.80024
TE₁₁ cutoff, 2/(a+b) estimate(f_c≈)
33.932
Peak voltage at breakdown(V_max)
1.6219
Breakdown-limited CW power (matched)(P_max)
26.919
  • Conductor loss assumes smooth, solid conductors. Braided shields and stranded centre conductors typically add 10–50 % to αc.

Formulas

Z0=η02πεrln⁡Dd,C′=2πε0εrln⁡(D/d),L′=μ02πln⁡DdZ_0 = \frac{\eta_0}{2\pi\sqrt{\varepsilon_r}}\ln\frac{D}{d},\qquad C' = \frac{2\pi\varepsilon_0\varepsilon_r}{\ln(D/d)},\qquad L' = \frac{\mu_0}{2\pi}\ln\frac{D}{d}αc=R′2Z0,R′=Rs2π(1a+1b),Rs=πfμ0σ;αd=πfεrtan⁡δc\alpha_c = \frac{R'}{2Z_0},\quad R' = \frac{R_s}{2\pi}\left(\frac{1}{a}+\frac{1}{b}\right),\quad R_s=\sqrt{\frac{\pi f\mu_0}{\sigma}};\qquad \alpha_d = \frac{\pi f\sqrt{\varepsilon_r}\tan\delta}{c}J1′(kca) Y1′(kcb)−J1′(kcb) Y1′(kca)=0,fc,TE11=c kc2πεr≈cπεr (a+b)J_1'(k_c a)\,Y_1'(k_c b) - J_1'(k_c b)\,Y_1'(k_c a) = 0,\quad f_{c,\mathrm{TE11}} = \frac{c\,k_c}{2\pi\sqrt{\varepsilon_r}} \approx \frac{c}{\pi\sqrt{\varepsilon_r}\,(a+b)}Emax⁡=Valn⁡(b/a)  ⇒  Vmax⁡=Ebd aln⁡ba,Pmax⁡=Vmax⁡22Z0E_{\max} = \frac{V}{a\ln(b/a)} \;\Rightarrow\; V_{\max} = E_{bd}\,a\ln\frac{b}{a},\qquad P_{\max} = \frac{V_{\max}^2}{2Z_0}

What this calculator does

A coaxial line is a round inner conductor of diameter dd inside a tubular shield whose inner diameter is DD, with the space between them filled by a dielectric of relative permittivity εr\varepsilon_r. The field is confined between the conductors and the medium is homogeneous, so the fundamental mode is a true TEM wave. That makes coax one of the few transmission lines with exact closed-form solutions:

Z0=η02πεrln⁡Dd,C′=2πε0εrln⁡(D/d),L′=μ02πln⁡Dd.Z_0 = \frac{\eta_0}{2\pi\sqrt{\varepsilon_r}}\ln\frac{D}{d},\qquad C' = \frac{2\pi\varepsilon_0\varepsilon_r}{\ln(D/d)},\qquad L' = \frac{\mu_0}{2\pi}\ln\frac{D}{d}.

The wave travels at c/εrc/\sqrt{\varepsilon_r}, so the velocity factor is 1/εr1/\sqrt{\varepsilon_r} and the delay is εr/c\sqrt{\varepsilon_r}/c per metre, independent of the geometry.

The calculator also gives you:

  • Conductor loss in the skin-effect regime. The resistance per length is R′=Rs2π(1a+1b)R' = \frac{R_s}{2\pi}\left(\frac1a + \frac1b\right) with Rs=πfμ0/σR_s = \sqrt{\pi f \mu_0/\sigma}, a=d/2a = d/2 and b=D/2b = D/2, and the loss is αc=R′/2Z0\alpha_c = R'/2Z_0. This is the high-frequency limit of Schelkunoff's exact solution.
  • Dielectric loss αd=πfεrtan⁡δ/c\alpha_d = \pi f\sqrt{\varepsilon_r}\tan\delta/c, exact for any homogeneous TEM line.
  • The TE₁₁ cutoff, the frequency above which the first waveguide mode can propagate. The calculator solves the exact Bessel-function eigenvalue equation (below) rather than using the usual estimate.
  • Peak voltage before breakdown. The field is strongest at the surface of the inner conductor, Emax=V/(aln⁡(b/a))E_\text{max} = V/(a\ln(b/a)), so a dielectric strength EbdE_{bd} allows Vmax=Ebd aln⁡(b/a)V_\text{max} = E_{bd}\,a\ln(b/a). The corresponding matched CW power is Pmax=Vmax2/2Z0P_\text{max} = V_\text{max}^2/2Z_0.

The TE₁₁ cutoff

The first higher-order mode of coax is TE₁₁. Its cutoff wavenumber kck_c is the lowest root of

J1′(kca) Y1′(kcb)−J1′(kcb) Y1′(kca)=0,fc=c kc2πεr.J_1'(k_c a)\,Y_1'(k_c b) - J_1'(k_c b)\,Y_1'(k_c a) = 0 , \qquad f_c = \frac{c\,k_c}{2\pi\sqrt{\varepsilon_r}} .

The familiar approximation kc≈2/(a+b)k_c \approx 2/(a+b), i.e. fc≈c/(πεr (D+d)/2)f_c \approx c/\left(\pi\sqrt{\varepsilon_r}\,(D+d)/2\right), treats the mode as a wave travelling around the mean circumference. The calculator shows both values. The estimate is conservative over the useful range:

D/dD/d1.52.33.32 (50 Ω air)471020
Error of 2/(a+b)2/(a+b) estimate−0.6 %−2.0 %−2.8 %−2.7 %−1.0 %+0.8 %+4.0 %

A negative error means the estimate predicts a cutoff that is too low. That is why connector series are rated slightly below the simple estimate: SMA (4.1 mm PTFE) is specified to about 18 GHz and 3.5 mm air line to about 34 GHz.

How to use solve-for

Click ⇄ Solve next to Inner conductor diameter or Outer conductor inner diameter, choose Characteristic impedance and enter your target. The calculator inverts the formula numerically while holding everything else fixed. Solving for εr\varepsilon_r from a measured impedance or velocity factor is a quick way to identify an unknown dielectric, for example foam versus solid PE. You can also target the TE₁₁ cutoff, which gives the largest shield that stays single-mode up to a given frequency.

Worked example

Take a 0.141″ semi-rigid geometry: d=0.92d = 0.92 mm, D=2.98D = 2.98 mm, PTFE with εr=2.08\varepsilon_r = 2.08 and tan⁡δ=0.0002\tan\delta = 0.0002, copper conductors (58 MS/m), at 1 GHz (these are the calculator's defaults).

  • Z0=48.86Z_0 = 48.86 Ω, velocity factor 69.34 %, delay 4.811 ns/m.
  • C′=98.46C' = 98.46 pF/m and L′=235.06L' = 235.06 nH/m.
  • Conductor loss 0.3320 dB/m and dielectric loss 0.02625 dB/m, so 0.3583 dB/m in total. At 1 GHz the conductors dominate.
  • TE₁₁ cutoff 34.89 GHz (the 2/(a+b)2/(a+b) estimate gives 33.93 GHz).
  • With a 3 kV/mm breakdown field (air, a conservative value for a PTFE line with air pockets), Vmax=1622V_\text{max} = 1622 V and Pmax=26.9P_\text{max} = 26.9 kW.

To get exactly 50 Ω with the same shield, solve for dd: the answer is d=0.8952d = 0.8952 mm.

Accuracy and validity

QuantityModelAccuracy
Z0Z_0, C′C', L′L', VF, delayExact TEM solutionExact for concentric, round conductors (limited by your εr\varepsilon_r)
αd\alpha_dExact for a homogeneous TEM lineExact (limited by your tan⁡δ\tan\delta)
αc\alpha_cSkin-effect limit of SchelkunoffWithin 1 % of the full Bessel solution once a≳5δa \gtrsim 5\delta
TE₁₁ cutoffExact eigenvalue equationBetter than 10⁻⁶
VmaxV_\text{max}, PmaxP_\text{max}Peak field at inner conductorExact field; breakdown itself depends on the material

These values were checked against scikit-rf's Coaxial media (Schelkunoff's Bessel-function conductor model) and against an independent SciPy solution of the TE₁₁ equation. L′L' is the external inductance only. Internal inductance adds a term that shrinks as δ/a\delta/a and is negligible above a few MHz.

Practical notes

  • Real cables lose more than the formula. Braided shields, stranded centre conductors, silver or tin plating and surface roughness typically add 10–50 % to the conductor loss. Use the manufacturer's attenuation curve for link budgets, and use this calculator to understand the trends.
  • Minimum loss and maximum power occur at different impedances. For an air line at fixed DD, conductor loss is lowest at D/d≈3.59D/d \approx 3.59 (about 77 Ω). Breakdown-limited power is highest at D/d≈1.65D/d \approx 1.65 (about 30 Ω). 50 Ω is the historical compromise between the two.
  • Dielectric strength needs derating. Datasheet values for PTFE or PE (tens of kV/mm) are short-term tests on thin films. Air gaps at connectors, humidity, altitude and VSWR all lower the usable value. Power in a mismatched line must be derated by the voltage standing-wave ratio, because the peak voltage rises by 1+∣Γ∣1+|\Gamma|.
  • The power figure is not a thermal rating. Average power handling is normally set by the temperature rise of the centre conductor, which depends on the jacket, the surroundings and the frequency. Use PmaxP_\text{max} as the breakdown ceiling for pulsed or high-voltage work.
  • Keep below TE₁₁. Connectors and bends convert energy into TE₁₁ once it can propagate, which shows up as sharp suck-outs in insertion loss. Choose the shield diameter so that the cutoff is comfortably above your highest frequency.

References

  1. D. M. Pozar, Microwave Engineering, 4th ed., Wiley, 2012, §2.1–2.2 and §3.5 (coaxial line parameters, attenuation, higher-order modes).
  2. S. A. Schelkunoff, “The Electromagnetic Theory of Coaxial Transmission Lines and Cylindrical Shields,” Bell System Technical Journal, vol. 13, no. 4, pp. 532–579, 1934.
  3. N. Marcuvitz, Waveguide Handbook, MIT Radiation Laboratory Series vol. 10, McGraw-Hill, 1951, §2.4 (coaxial waveguide modes).
  4. M. Abramowitz and I. A. Stegun, Handbook of Mathematical Functions, NBS AMS 55, 1964, eqs. 9.1.10–9.1.13 (Bessel series).

This calculator's results are checked against 38 independent reference values in automated tests on every change. How we check accuracy.