What this calculator does
A plated through-hole via is a short copper tube, drilled through the board and plated on its inside wall. It connects layers, and it brings the usual parasitics with it. This calculator gives you:
- the DC resistance of the barrel, from the plated annulus, at 20 °C and at the operating temperature;
- the inductance and capacitance of the via, from Howard Johnson's closed-form estimates, and the impedance these imply;
- an IPC-2221 current estimate: the maximum current for an allowed temperature rise, and the rise at your current;
- the thermal resistance of the copper barrel, which matters for thermal vias under power parts;
- the aspect ratio (board thickness ÷ drill), with a manufacturability warning.
Geometry
The drilled diameter is the outer diameter of the copper tube. Plating of thickness lines the hole, so the finished hole is and the copper cross-section is
The resistance is with the copper temperature coefficient of 0.00393 /°C. The thermal resistance of the barrel along its length is , with W/(m·K). That is a typical design value for electroplated copper, a little below the 401 W/(m·K) of pure copper.
Johnson's inductance and capacitance
In High-Speed Digital Design (§7.4), Johnson gives two quick estimates, with dimensions in inches:
Here is the via length, the barrel diameter, the board thickness, the pad diameter and the diameter of the clearance hole (antipad) in the planes. This calculator takes . The inductance formula is the partial self-inductance of a straight round conductor. It sets an upper bound in practice: the loop inductance that matters depends on where the return current flows, usually through a nearby ground via.
Current
The current estimate applies the IPC-2221 external-conductor equation to the barrel cross-section in square mils. There is no IPC chart for vias, so treat this as an estimate. A via is short and well heat-sunk by its pads and the planes it touches, so it usually runs cooler than a trace of the same cross-section.
How to use solve-for
- Solve Drilled hole diameter for Inductance or Barrel resistance to size a via for a parasitic budget.
- Solve Antipad diameter for Via impedance to find the clearance that makes the via look like 50 Ω. The answer is only as good as Johnson's capacitance estimate, so confirm it with a field solver.
- Solve Plating thickness for Max current to see what plating a power via would need.
Worked example
A typical via on a 1.6 mm board: 0.3 mm drill, 25 µm plating, 0.6 mm pad, 1.0 mm antipad, , carrying 1 A at 25 °C ambient.
| Quantity | Result |
|---|---|
| Barrel cross-section | 0.0216 mm² (33.5 mil²) |
| Barrel resistance at 20 °C | 1.277 mΩ |
| Inductance / capacitance | 1.299 nH / 0.586 pF |
| Via impedance | 47.1 Ω |
| Max current for a 10 °C rise | 1.69 A |
| Rise at 1 A, resistance when hot | 3.05 °C, 1.318 mΩ |
| Barrel thermal resistance | 189.9 °C/W |
| Aspect ratio | 5.33 : 1 |
Thermal resistance is the number to watch for thermal vias. One of these vias conducts only about 0.5 W per 100 °C of drop, which is why exposed-pad packages use arrays of 9–25 vias. Ten vias in parallel give about 19 °C/W.
Accuracy and validity
| Quantity | Model | Accuracy |
|---|---|---|
| Resistance, thermal resistance | Exact for a uniform tube | Limited by the real plating thickness (thinner in the barrel centre) and the plated copper's conductivity |
| Inductance | Johnson, partial inductance of a rod | Rough; assumes . The return path decides the loop inductance |
| Capacitance | Johnson, pad-to-plane estimate | Rough; field solvers and measurements often differ by tens of percent |
| Current | IPC-2221 external equation on the barrel | An estimate; vias usually run cooler |
Johnson presents both parasitic formulas as rough estimates for checking whether a via matters at a given rise time, not as accurate models. Published 3D-solver results for real vias show that the capacitance depends strongly on the number of planes the via passes and on their clearances. Above a few GHz, or for backplane vias with stubs, use a field solver or a measured model. For those cases a via is a short transmission line, and the stub resonance often dominates.
Practical notes
- Aspect ratio. Fabricators plate reliably up to about 8:1 on standard processes and 10:1 on advanced ones. Above that, the plating in the middle of the barrel becomes thin. The calculator flags anything over 8:1 and warns above 10:1.
- Plating thickness. IPC-6012 Class 2 usually calls for an average of 20 µm (0.8 mil) of copper in the hole, and Class 3 for 25 µm (1 mil). The minimum at the thinnest point is lower, so design power vias on the minimum.
- Use several vias for current. Several small vias carry more current, with less inductance, than one large via of the same copper area, and they give redundancy.
- Antipads trade capacitance for plane integrity. Larger clearances reduce via capacitance, but they perforate the planes and can cut return paths under nearby traces.
- Back-drill the stubs. On thick high-speed boards, the unused part of the barrel acts as an open stub. Back-drilling it shortens the via, which removes a resonance and reduces the capacitance.