Skip to content
FiftyOhm
Esc
  • Air-core coilSingle-layer air-core solenoid inductance from Nagaoka's exact coefficient, compared with Wheeler's formula. Solve for the number of turns for a target inductance.Components & magnetics
  • Attenuator PadsResistor values for Pi, T, bridged-T and minimum-loss L-pad attenuators, with unequal impedances, power dissipation per resistor and E24/E96 rounding.Couplers, dividers & attenuators
  • CoaxCoax Z0, capacitance and inductance per length, velocity factor, loss, exact TE11 cutoff and breakdown voltage. Solve for D, d or εr from Z0.Transmission lines
  • CPW / GCPWCoplanar waveguide and grounded CPW impedance, effective permittivity, dispersion, delay and loss by conformal mapping. Solve for centre width or gap.Transmission lines
  • dBm ↔ W ↔ VConvert RF power between dBm, dBW, watts, Vrms, Vpeak, Vpp, dBµV and dBmV for any system impedance. Instant, accurate, with formulas.Fundamentals & conversions
  • Differential pairEdge-coupled microstrip and stripline differential impedance, Z0 even/odd, common-mode impedance, coupling and delay. Solve for spacing or width from Zdiff.Transmission lines
  • Filter OrderMinimum filter order to meet a passband/stopband attenuation mask for Butterworth, Chebyshev and elliptic responses, with the attenuation actually achieved.Filters
  • Free-space path lossFree-space path loss from the Friis equation, received power with antenna gains, and a far-field check. Solve for distance or frequency.Propagation & link budget
  • L / Pi / T MatchingDesign lumped L, Pi and T matching networks between complex source and load impedances. Both L solutions, loaded-Q Pi/T, component values and bandwidth.Matching & Smith chart
  • LC Filter DesignerDesign lumped LC ladder filters: Butterworth, Chebyshev or Bessel; low-pass, high-pass, band-pass, band-stop to order 10, with exact insertion loss and group delay.Filters
  • MicrostripMicrostrip Z0, effective permittivity, dispersion, delay and loss. Solve for trace width from target impedance. Hammerstad–Jensen + Kirschning–Jansen models.Transmission lines

PCB Via Calculator: Resistance, Inductance, Capacitance and Current

Plated via barrel resistance, inductance and capacitance (Howard Johnson), IPC-2221 current estimate, thermal resistance and aspect-ratio DFM check.

5 cited sources10 reference checksRuns in your browser

Inputs

Outer diameter of the plated barrel. The finished hole is d − 2·tₚ.

Annealed copper (IACS) is 58.0 MS/m. Electroplated barrel copper is often 10–20 % lower.

Results

Barrel resistance at 20 °C(R₂₀)
1.2772
Inductance (Johnson)(L)
1.2993
Capacitance (Johnson)(C)
586.2
Max current at ΔT (IPC-2221 estimate)(I_max)
1.6853
Temperature rise at I (IPC-2221 estimate)
3.0535
Barrel resistance at operating temperature(R)
1.3177
Voltage drop at I
1.3177
Power loss at I
1.3177
Barrel thermal resistance(θ)
189.95
Via impedance √(L/C)(Z_via)
47.079Ω
Aspect ratio h/d
5.33
Barrel cross-section(A)
33.478
Finished hole diameter
9.8425
  • L and C are Johnson's rough closed-form estimates; field-solver or measured values can differ by tens of percent. The current is an IPC-2221 estimate applied to the barrel cross-section: real vias are cooled by pads and planes and usually run cooler.

Formulas

A=π[(d2)2−(d2−tp)2],R=hσ20A[1+0.00393 (T−20 ∘C)]A = \pi\left[\left(\tfrac{d}{2}\right)^2 - \left(\tfrac{d}{2}-t_p\right)^2\right],\quad R = \frac{h}{\sigma_{20}A}\left[1+0.00393\,(T-20\,^\circ\mathrm{C})\right]L=5.08 h[ln⁡4hd+1] nH(h,d in inches)L = 5.08\,h\left[\ln\frac{4h}{d}+1\right]\ \text{nH}\quad (h, d\ \text{in inches})C=1.41 εr T D1D2−D1 pF(T=h, D1,D2 in inches)C = \frac{1.41\,\varepsilon_r\,T\,D_1}{D_2 - D_1}\ \text{pF}\quad (T = h,\ D_1, D_2\ \text{in inches})Imax=0.048 ΔT0.44A0.725 (A in mil2),θ=hkCuA, kCu=390 W/(m K)I_\text{max} = 0.048\,\Delta T^{0.44} A^{0.725}\ (A\ \text{in mil}^2),\qquad \theta = \frac{h}{k_\text{Cu} A},\ k_\text{Cu} = 390\ \mathrm{W/(m\,K)}

What this calculator does

A plated through-hole via is a short copper tube, drilled through the board and plated on its inside wall. It connects layers, and it brings the usual parasitics with it. This calculator gives you:

  • the DC resistance of the barrel, from the plated annulus, at 20 °C and at the operating temperature;
  • the inductance and capacitance of the via, from Howard Johnson's closed-form estimates, and the impedance L/C\sqrt{L/C} these imply;
  • an IPC-2221 current estimate: the maximum current for an allowed temperature rise, and the rise at your current;
  • the thermal resistance of the copper barrel, which matters for thermal vias under power parts;
  • the aspect ratio (board thickness ÷ drill), with a manufacturability warning.

Geometry

The drilled diameter dd is the outer diameter of the copper tube. Plating of thickness tpt_p lines the hole, so the finished hole is d−2tpd - 2t_p and the copper cross-section is

A=π[(d2)2−(d2−tp)2].A = \pi\left[\left(\tfrac{d}{2}\right)^2 - \left(\tfrac{d}{2} - t_p\right)^2\right].

The resistance is R=h/(σA)R = h/(\sigma A) with the copper temperature coefficient of 0.00393 /°C. The thermal resistance of the barrel along its length is θ=h/(kCuA)\theta = h/(k_\text{Cu}A), with kCu=390k_\text{Cu} = 390 W/(m·K). That is a typical design value for electroplated copper, a little below the 401 W/(m·K) of pure copper.

Johnson's inductance and capacitance

In High-Speed Digital Design (§7.4), Johnson gives two quick estimates, with dimensions in inches:

L=5.08 h[ln⁡4hd+1] nH,C=1.41 εr T D1D2−D1 pFL = 5.08\,h\left[\ln\frac{4h}{d} + 1\right]\ \text{nH},\qquad C = \frac{1.41\,\varepsilon_r\,T\,D_1}{D_2 - D_1}\ \text{pF}

Here hh is the via length, dd the barrel diameter, TT the board thickness, D1D_1 the pad diameter and D2D_2 the diameter of the clearance hole (antipad) in the planes. This calculator takes T=hT = h. The inductance formula is the partial self-inductance of a straight round conductor. It sets an upper bound in practice: the loop inductance that matters depends on where the return current flows, usually through a nearby ground via.

Current

The current estimate applies the IPC-2221 external-conductor equation I=0.048 ΔT0.44A0.725I = 0.048\,\Delta T^{0.44}A^{0.725} to the barrel cross-section in square mils. There is no IPC chart for vias, so treat this as an estimate. A via is short and well heat-sunk by its pads and the planes it touches, so it usually runs cooler than a trace of the same cross-section.

How to use solve-for

  • Solve Drilled hole diameter for Inductance or Barrel resistance to size a via for a parasitic budget.
  • Solve Antipad diameter for Via impedance to find the clearance that makes the via look like 50 Ω. The answer is only as good as Johnson's capacitance estimate, so confirm it with a field solver.
  • Solve Plating thickness for Max current to see what plating a power via would need.

Worked example

A typical via on a 1.6 mm board: 0.3 mm drill, 25 µm plating, 0.6 mm pad, 1.0 mm antipad, εr=4.4\varepsilon_r = 4.4, carrying 1 A at 25 °C ambient.

QuantityResult
Barrel cross-section0.0216 mm² (33.5 mil²)
Barrel resistance at 20 °C1.277 mΩ
Inductance / capacitance1.299 nH / 0.586 pF
Via impedance L/C\sqrt{L/C}47.1 Ω
Max current for a 10 °C rise1.69 A
Rise at 1 A, resistance when hot3.05 °C, 1.318 mΩ
Barrel thermal resistance189.9 °C/W
Aspect ratio5.33 : 1

Thermal resistance is the number to watch for thermal vias. One of these vias conducts only about 0.5 W per 100 °C of drop, which is why exposed-pad packages use arrays of 9–25 vias. Ten vias in parallel give about 19 °C/W.

Accuracy and validity

QuantityModelAccuracy
Resistance, thermal resistanceExact for a uniform tubeLimited by the real plating thickness (thinner in the barrel centre) and the plated copper's conductivity
InductanceJohnson, partial inductance of a rodRough; assumes h≫dh \gg d. The return path decides the loop inductance
CapacitanceJohnson, pad-to-plane estimateRough; field solvers and measurements often differ by tens of percent
CurrentIPC-2221 external equation on the barrelAn estimate; vias usually run cooler

Johnson presents both parasitic formulas as rough estimates for checking whether a via matters at a given rise time, not as accurate models. Published 3D-solver results for real vias show that the capacitance depends strongly on the number of planes the via passes and on their clearances. Above a few GHz, or for backplane vias with stubs, use a field solver or a measured model. For those cases a via is a short transmission line, and the stub resonance often dominates.

Practical notes

  • Aspect ratio. Fabricators plate reliably up to about 8:1 on standard processes and 10:1 on advanced ones. Above that, the plating in the middle of the barrel becomes thin. The calculator flags anything over 8:1 and warns above 10:1.
  • Plating thickness. IPC-6012 Class 2 usually calls for an average of 20 µm (0.8 mil) of copper in the hole, and Class 3 for 25 µm (1 mil). The minimum at the thinnest point is lower, so design power vias on the minimum.
  • Use several vias for current. Several small vias carry more current, with less inductance, than one large via of the same copper area, and they give redundancy.
  • Antipads trade capacitance for plane integrity. Larger clearances reduce via capacitance, but they perforate the planes and can cut return paths under nearby traces.
  • Back-drill the stubs. On thick high-speed boards, the unused part of the barrel acts as an open stub. Back-drilling it shortens the via, which removes a resonance and reduces the capacitance.

References

  1. H. W. Johnson and M. Graham, High-Speed Digital Design: A Handbook of Black Magic, Prentice Hall, 1993, §7.4 “Vias”.
  2. IPC-2221B, Generic Standard on Printed Board Design, IPC, 2012, §6.2 and Fig. 6-4.
  3. IEC 60028, International Standard of Resistance for Copper, 1925 (ρ₂₀ = 1/58 Ω·mm²/m, α₂₀ = 0.00393 /°C).
  4. CRC Handbook of Chemistry and Physics, CRC Press, “Thermal Conductivity of Metals and Semiconductors as a Function of Temperature” (Cu: 401 W/m·K at 300 K).
  5. IPC-6012, Qualification and Performance Specification for Rigid Printed Boards, IPC (minimum via plating thickness by class).

This calculator's results are checked against 10 independent reference values in automated tests on every change. How we check accuracy.