What this tool does
The Smith chart is the reflection-coefficient plane with the impedance coordinates drawn on it. Every passive impedance maps to one point inside the unit circle through
Phillip Smith published it in 1939 as a graphical transmission-line calculator. It is still the standard way to see a matching problem: how far a load is from , which component moves it in which direction, and how much bandwidth a network is likely to have. This tool draws the chart from those equations. You enter a load and build a network of series and shunt R, L and C, transmission lines and stubs, element by element. It cascades the network from the load toward the source and draws the path that each element traces.
The numbers come from exact circuit equations, not from reading the chart. Lumped elements add impedance (series) or admittance (shunt). Lines use the full input-impedance relation with a complex propagation constant, so loss is included:
Reading the chart
- The center is : a perfect match, . The outer circle is , where every lossless reactance lies. The left end is a short and the right end is an open.
- Constant-resistance circles all touch the right-hand point. The circle through the center is . A series reactance moves a point along its constant- circle: clockwise for an inductor and anticlockwise for a capacitor.
- Constant-reactance arcs leave the right-hand point. The upper half is inductive () and the lower half is capacitive ().
- The admittance grid (dashed, toggleable) is the impedance grid rotated by 180°. A shunt element moves a point along its constant-conductance circle: clockwise for a capacitor and anticlockwise for an inductor.
- A transmission line of rotates the point clockwise about the center, toward the generator, by . A full turn is . Loss spirals the point inward by . A line with a different rotates about instead, so its path on the chart is a circle that is not centered.
- The VSWR circle is the circle of constant through the input point. Every point on it has the same VSWR and return loss.
- Constant-Q contours are the arcs through both ends of the real axis. The loaded Q of an L-section is roughly the highest nodal Q that its path reaches. To keep a network broadband, keep its path inside a low-Q contour.
Hover over the chart, or focus it and use the arrow keys, to read , and at the cursor. The cursor also draws the circle and arc that pass through it. Click a node marker to pin its values. Every node is also listed in the table below the chart.
Building a network
Elements are listed from the load toward the source. The first element is soldered to the load, and the last one faces the generator. Use the arrow buttons to reorder elements, the series/shunt switch to change how a component or stub is connected, and the slider on each card to tune it. The slider spans a decade either side of the last value you typed. For lines it spans 0–180°. Line and stub lengths can be electrical (degrees at the design frequency, scaling with frequency like a TEM line) or physical (length and ). Loss is constant with frequency: a total in dB for electrical lengths, or dB per metre for physical ones.
Mismatch loss is computed against a source impedance , which defaults to :
which reduces to for a real . Set a complex to check a conjugate match to an amplifier.
Frequency sweep plots the locus of from to on the chart, and draws below it. The load can stay fixed, or it can behave like a resistor in series with the inductor or capacitor that gives its reactance at . The CSV export contains , , VSWR and return loss at every point. Copy share link encodes the load, the network and the options in the URL.
Worked example: an L-section at 1 GHz
Match to at 1 GHz. This is the tool's default state, and it is also the first entry under Examples.
- Plot the load. . The tool shows , VSWR 3.494 and return loss 5.115 dB. The load sits in the lower (capacitive) half, inside the circle.
- Choose the topology. Because , the point has to reach the circle (the admittance-grid circle through the center) with a series element first. Then a shunt element rides that circle to the center. Pozar's L-section equations for this case give and . With and , the first solution is and mS.
- Series inductor. nH. Add Series L and enter 10.35 nH. The trace follows the circle clockwise to node 1, where and mS. This point lies on the circle, as intended. Its nodal Q is exactly 1.
- Shunt capacitor. pF. Add Shunt C. The trace follows the circle clockwise to the center. The results panel shows , VSWR 1 : 1 and mismatch loss 0 dB.
The other solution, (2.387 nH) followed by mS (a 7.958 nH shunt inductor), goes through instead. Try it: change the shunt capacitor into a shunt inductor and retune the slider.
Bandwidth. Turn on the sweep (0.5–1.5 GHz). With the load fixed, the 10 dB return-loss band runs from about 0.71 to 1.21 GHz, and the 20 dB band from about 0.93 to 1.07 GHz. If you model the load as 25 Ω in series with a capacitor ("R + series L or C"), the load's own reactance changes with frequency, and the 10 dB band narrows to about 0.84–1.15 GHz. That difference is why a real load model matters more than the network topology.
To check the tool against textbook values, the Examples menu also loads three examples from Pozar. Example 5.1 is an L-section matching 200 − j100 Ω to 100 Ω at 500 MHz with a 0.92 pF shunt capacitor and a 38.8 nH series inductor. Example 5.2 is a single short-circuited shunt stub matching 60 − j80 Ω, with d = 0.110λ and ℓ = 0.095λ. The third example is a 70.7 Ω quarter-wave transformer from 100 Ω to 50 Ω.
Accuracy and validity
| Part | Model | Checked against |
|---|---|---|
| Z ↔ Γ ↔ Y, VSWR, RL | Exact definitions | Closed-form values (z = 1 + j1 gives VSWR = φ²) |
| Lines and stubs | TEM line, complex γ, any | λ/4 inverts z, λ/2 is the identity, decay |
| Cascades and sweeps | Exact two-port cascade | scikit-rf 2.2 to about 10⁻⁹ |
| Matching examples | — | Pozar Examples 5.1, 5.2 and 5.3 |
The element models are ideal. Real inductors have self-resonance and finite Q, capacitors have ESR and ESL, and microstrip stubs need open-end and T-junction corrections. Electrical lengths assume a dispersionless TEM line, and loss is held constant over the sweep. The chart is a single-frequency picture: a network that reaches the center at may leave it quickly away from . Use the sweep to check the band.
Practical notes
- Prefer topologies whose path stays inside a low-Q contour. Two-step (four-element) networks through an intermediate resistance give more bandwidth than one high-Q L-section.
- A shunt short stub at the load end of a line also gives a DC return path. An open stub does not.
- Series stubs are awkward in microstrip and coplanar waveguide, so shunt stubs are usually preferred.
- Normalize to the impedance you actually care about. For an amplifier input, set to the conjugate of the device's optimum source impedance, and read the mismatch loss directly.
- To compare with S-parameter files, note that in dB is the negative of the return loss shown here.