Skip to content
FiftyOhm
Esc
  • Air-core coilSingle-layer air-core solenoid inductance from Nagaoka's exact coefficient, compared with Wheeler's formula. Solve for the number of turns for a target inductance.Components & magnetics
  • Attenuator PadsResistor values for Pi, T, bridged-T and minimum-loss L-pad attenuators, with unequal impedances, power dissipation per resistor and E24/E96 rounding.Couplers, dividers & attenuators
  • CoaxCoax Z0, capacitance and inductance per length, velocity factor, loss, exact TE11 cutoff and breakdown voltage. Solve for D, d or εr from Z0.Transmission lines
  • CPW / GCPWCoplanar waveguide and grounded CPW impedance, effective permittivity, dispersion, delay and loss by conformal mapping. Solve for centre width or gap.Transmission lines
  • dBm ↔ W ↔ VConvert RF power between dBm, dBW, watts, Vrms, Vpeak, Vpp, dBµV and dBmV for any system impedance. Instant, accurate, with formulas.Fundamentals & conversions
  • Differential pairEdge-coupled microstrip and stripline differential impedance, Z0 even/odd, common-mode impedance, coupling and delay. Solve for spacing or width from Zdiff.Transmission lines
  • Filter OrderMinimum filter order to meet a passband/stopband attenuation mask for Butterworth, Chebyshev and elliptic responses, with the attenuation actually achieved.Filters
  • Free-space path lossFree-space path loss from the Friis equation, received power with antenna gains, and a far-field check. Solve for distance or frequency.Propagation & link budget
  • L / Pi / T MatchingDesign lumped L, Pi and T matching networks between complex source and load impedances. Both L solutions, loaded-Q Pi/T, component values and bandwidth.Matching & Smith chart
  • LC Filter DesignerDesign lumped LC ladder filters: Butterworth, Chebyshev or Bessel; low-pass, high-pass, band-pass, band-stop to order 10, with exact insertion loss and group delay.Filters
  • MicrostripMicrostrip Z0, effective permittivity, dispersion, delay and loss. Solve for trace width from target impedance. Hammerstad–Jensen + Kirschning–Jansen models.Transmission lines

Interactive Smith Chart Calculator

Interactive Smith chart: plot a load, add series/shunt L, C, R, lines and stubs, and read Zin, Γ, VSWR and return loss along a matching network.

4 cited sources32 reference checksRuns in your browser

Smith chart

00.20.5125∞+j0.2−j0.2+j0.5−j0.5+j1−j1+j2−j2+j5−j51: Series inductor2: Shunt capacitorLoad: Z = 25 − j40 Ω, Γ = 0.5549 ∠ −93.93°, VSWR 3.494 : 1LNode 1: Z = 25 + j25 Ω, Γ = 0.4472 ∠ 116.6°, VSWR 2.618 : 11Input: Z = 50 + j0 Ω, Γ = 0, VSWR 1 : 1IN
Hover the chart (or focus it and use the arrow keys) to read Z, Y and Γ. Click a node to pin its values.

Load & system

Load: Γ = 0.5549 ∠ −93.93°, z = 0.5 − j0.8

Matching network

Elements are listed from the load toward the source.

  1. Element 1: Series inductor

    X = +65 Ω at 1 GHz

  2. Element 2: Shunt capacitor

    B = +20 mS at 1 GHz

Results

Input impedance Zin
50 + j0 Ω
VSWR
1 : 1
Return loss
> 80 dB
Γin
0
Normalized zin
1 + j0
Yin
20 + j0 mS
Nodal Q
0
Mismatch loss vs Zs = 50 + j0 Ω
0 dB

Node values at 1 GHz

NodeZ (Ω)Y (mS)ΓVSWRRLQ
Load25 − j4011.24 + j17.980.5549 ∠ −93.93°3.494 : 15.115 dB1.6
1. after series inductor25 + j2520 − j200.4472 ∠ 116.6°2.618 : 16.99 dB1
2. after shunt capacitor (input)50 + j020 + j001 : 1> 80 dB0

Formulas

Γ=ZL−Z0ZL+Z0=z−1z+1,z=ZLZ0=r+jx\Gamma = \frac{Z_L - Z_0}{Z_L + Z_0} = \frac{z - 1}{z + 1},\qquad z = \frac{Z_L}{Z_0} = r + jxVSWR=1+∣Γ∣1−∣Γ∣,RL=−20log⁡10∣Γ∣,ML=−10log⁡10 ⁣(1−∣Γ∣2)\mathrm{VSWR} = \frac{1+|\Gamma|}{1-|\Gamma|},\qquad \mathrm{RL} = -20\log_{10}|\Gamma|,\qquad \mathrm{ML} = -10\log_{10}\!\left(1-|\Gamma|^2\right)r circles: (Γr−r1+r)2+Γi2=(11+r)2,x circles: (Γr−1)2+(Γi−1x)2=1x2r\text{ circles: } \left(\Gamma_r - \tfrac{r}{1+r}\right)^2 + \Gamma_i^2 = \left(\tfrac{1}{1+r}\right)^2,\qquad x\text{ circles: } (\Gamma_r - 1)^2 + \left(\Gamma_i - \tfrac{1}{x}\right)^2 = \tfrac{1}{x^2}Zin=Zc ZL+Zctanh⁡γℓZc+ZLtanh⁡γℓ,Γin=ΓL e−2γℓ  (Zc=Z0)Z_\mathrm{in} = Z_c\,\frac{Z_L + Z_c\tanh\gamma\ell}{Z_c + Z_L\tanh\gamma\ell},\qquad \Gamma_\mathrm{in} = \Gamma_L\,e^{-2\gamma\ell}\ \ (Z_c = Z_0)Zstubshort=jZctan⁡βℓ,Zstubopen=−jZccot⁡βℓ,Qn=∣x∣r=∣b∣gZ^\mathrm{short}_\mathrm{stub} = jZ_c\tan\beta\ell,\qquad Z^\mathrm{open}_\mathrm{stub} = -jZ_c\cot\beta\ell,\qquad Q_n = \frac{|x|}{r} = \frac{|b|}{g}MLZs=−10log⁡104RsRin∣Zs+Zin∣2\mathrm{ML}_{Z_s} = -10\log_{10}\frac{4R_sR_\mathrm{in}}{|Z_s + Z_\mathrm{in}|^2}

What this tool does

The Smith chart is the reflection-coefficient plane with the impedance coordinates drawn on it. Every passive impedance ZZ maps to one point inside the unit circle through

Γ=Z−Z0Z+Z0=z−1z+1,z=ZZ0.\Gamma = \frac{Z - Z_0}{Z + Z_0} = \frac{z-1}{z+1}, \qquad z = \frac{Z}{Z_0}.

Phillip Smith published it in 1939 as a graphical transmission-line calculator. It is still the standard way to see a matching problem: how far a load is from Z0Z_0, which component moves it in which direction, and how much bandwidth a network is likely to have. This tool draws the chart from those equations. You enter a load and build a network of series and shunt R, L and C, transmission lines and stubs, element by element. It cascades the network from the load toward the source and draws the path that each element traces.

The numbers come from exact circuit equations, not from reading the chart. Lumped elements add impedance (series) or admittance (shunt). Lines use the full input-impedance relation with a complex propagation constant, so loss is included:

Zin=Zc ZL+Zctanh⁡γℓZc+ZLtanh⁡γℓ.Z_\mathrm{in} = Z_c\,\frac{Z_L + Z_c\tanh\gamma\ell}{Z_c + Z_L\tanh\gamma\ell}.

Reading the chart

  • The center is z=1z = 1: a perfect match, Γ=0\Gamma = 0. The outer circle is ∣Γ∣=1|\Gamma| = 1, where every lossless reactance lies. The left end is a short and the right end is an open.
  • Constant-resistance circles all touch the right-hand point. The circle through the center is r=1r = 1. A series reactance moves a point along its constant-rr circle: clockwise for an inductor and anticlockwise for a capacitor.
  • Constant-reactance arcs leave the right-hand point. The upper half is inductive (+jx+jx) and the lower half is capacitive (−jx-jx).
  • The admittance grid (dashed, toggleable) is the impedance grid rotated by 180°. A shunt element moves a point along its constant-conductance circle: clockwise for a capacitor and anticlockwise for an inductor.
  • A transmission line of Zc=Z0Z_c = Z_0 rotates the point clockwise about the center, toward the generator, by 2βℓ2\beta\ell. A full turn is λ/2\lambda/2. Loss spirals the point inward by e−2αℓe^{-2\alpha\ell}. A line with a different ZcZ_c rotates about ZcZ_c instead, so its path on the Z0Z_0 chart is a circle that is not centered.
  • The VSWR circle is the circle of constant ∣Γ∣|\Gamma| through the input point. Every point on it has the same VSWR and return loss.
  • Constant-Q contours are the arcs ∣x∣/r=Q|x|/r = Q through both ends of the real axis. The loaded Q of an L-section is roughly the highest nodal Q that its path reaches. To keep a network broadband, keep its path inside a low-Q contour.

Hover over the chart, or focus it and use the arrow keys, to read ZZ, YY and Γ\Gamma at the cursor. The cursor also draws the rr circle and xx arc that pass through it. Click a node marker to pin its values. Every node is also listed in the table below the chart.

Building a network

Elements are listed from the load toward the source. The first element is soldered to the load, and the last one faces the generator. Use the arrow buttons to reorder elements, the series/shunt switch to change how a component or stub is connected, and the slider on each card to tune it. The slider spans a decade either side of the last value you typed. For lines it spans 0–180°. Line and stub lengths can be electrical (degrees at the design frequency, scaling with frequency like a TEM line) or physical (length and εeff\varepsilon_\mathrm{eff}). Loss is constant with frequency: a total in dB for electrical lengths, or dB per metre for physical ones.

Mismatch loss is computed against a source impedance ZsZ_s, which defaults to Z0Z_0:

ML=−10log⁡104RsRin∣Zs+Zin∣2,\mathrm{ML} = -10\log_{10}\frac{4R_sR_\mathrm{in}}{|Z_s + Z_\mathrm{in}|^2},

which reduces to −10log⁡10(1−∣Γ∣2)-10\log_{10}(1-|\Gamma|^2) for a real ZsZ_s. Set a complex ZsZ_s to check a conjugate match to an amplifier.

Frequency sweep plots the locus of ZinZ_\mathrm{in} from f1f_1 to f2f_2 on the chart, and draws ∣S11∣|S_{11}| below it. The load can stay fixed, or it can behave like a resistor in series with the inductor or capacitor that gives its reactance at ff. The CSV export contains ZinZ_\mathrm{in}, Γ\Gamma, VSWR and return loss at every point. Copy share link encodes the load, the network and the options in the URL.

Worked example: an L-section at 1 GHz

Match ZL=25−j40 ΩZ_L = 25 - j40\ \Omega to 50 Ω50\ \Omega at 1 GHz. This is the tool's default state, and it is also the first entry under Examples.

  1. Plot the load. zL=0.5−j0.8z_L = 0.5 - j0.8. The tool shows ΓL=0.5549∠−93.93°\Gamma_L = 0.5549\angle -93.93°, VSWR 3.494 and return loss 5.115 dB. The load sits in the lower (capacitive) half, inside the r=1r = 1 circle.
  2. Choose the topology. Because RL<Z0R_L < Z_0, the point has to reach the g=1g = 1 circle (the admittance-grid circle through the center) with a series element first. Then a shunt element rides that circle to the center. Pozar's L-section equations for this case give X=±RL(Z0−RL)−XLX = \pm\sqrt{R_L(Z_0 - R_L)} - X_L and B=±(Z0−RL)/RL /Z0B = \pm\sqrt{(Z_0 - R_L)/R_L}\,/Z_0. With RL=25R_L = 25 and XL=−40X_L = -40, the first solution is X=25+40=65 ΩX = 25 + 40 = 65\ \Omega and B=+20B = +20 mS.
  3. Series inductor. L=X/ω=65/(2π⋅109)=10.35L = X/\omega = 65/(2\pi\cdot 10^9) = 10.35 nH. Add Series L and enter 10.35 nH. The trace follows the r=0.5r = 0.5 circle clockwise to node 1, where Z=25+j25 ΩZ = 25 + j25\ \Omega and Y=20−j20Y = 20 - j20 mS. This point lies on the g=1g = 1 circle, as intended. Its nodal Q is exactly 1.
  4. Shunt capacitor. C=B/ω=0.020/(2π⋅109)=3.183C = B/\omega = 0.020/(2\pi\cdot10^9) = 3.183 pF. Add Shunt C. The trace follows the g=1g = 1 circle clockwise to the center. The results panel shows Zin=50+j0 ΩZ_\mathrm{in} = 50 + j0\ \Omega, VSWR 1 : 1 and mismatch loss 0 dB.

The other solution, X=−25+40=15 ΩX = -25 + 40 = 15\ \Omega (2.387 nH) followed by B=−20B = -20 mS (a 7.958 nH shunt inductor), goes through 25−j25 Ω25 - j25\ \Omega instead. Try it: change the shunt capacitor into a shunt inductor and retune the slider.

Bandwidth. Turn on the sweep (0.5–1.5 GHz). With the load fixed, the 10 dB return-loss band runs from about 0.71 to 1.21 GHz, and the 20 dB band from about 0.93 to 1.07 GHz. If you model the load as 25 Ω in series with a capacitor ("R + series L or C"), the load's own reactance changes with frequency, and the 10 dB band narrows to about 0.84–1.15 GHz. That difference is why a real load model matters more than the network topology.

To check the tool against textbook values, the Examples menu also loads three examples from Pozar. Example 5.1 is an L-section matching 200 − j100 Ω to 100 Ω at 500 MHz with a 0.92 pF shunt capacitor and a 38.8 nH series inductor. Example 5.2 is a single short-circuited shunt stub matching 60 − j80 Ω, with d = 0.110λ and ℓ = 0.095λ. The third example is a 70.7 Ω quarter-wave transformer from 100 Ω to 50 Ω.

Accuracy and validity

PartModelChecked against
Z ↔ Γ ↔ Y, VSWR, RLExact definitionsClosed-form values (z = 1 + j1 gives VSWR = φ²)
Lines and stubsTEM line, complex γ, any ZcZ_cλ/4 inverts z, λ/2 is the identity, e−2αℓe^{-2\alpha\ell} decay
Cascades and sweepsExact two-port cascadescikit-rf 2.2 to about 10⁻⁹
Matching examples—Pozar Examples 5.1, 5.2 and 5.3

The element models are ideal. Real inductors have self-resonance and finite Q, capacitors have ESR and ESL, and microstrip stubs need open-end and T-junction corrections. Electrical lengths assume a dispersionless TEM line, and loss is held constant over the sweep. The chart is a single-frequency picture: a network that reaches the center at ff may leave it quickly away from ff. Use the sweep to check the band.

Practical notes

  • Prefer topologies whose path stays inside a low-Q contour. Two-step (four-element) networks through an intermediate resistance give more bandwidth than one high-Q L-section.
  • A shunt short stub at the load end of a line also gives a DC return path. An open stub does not.
  • Series stubs are awkward in microstrip and coplanar waveguide, so shunt stubs are usually preferred.
  • Normalize to the impedance you actually care about. For an amplifier input, set ZsZ_s to the conjugate of the device's optimum source impedance, and read the mismatch loss directly.
  • To compare with S-parameter files, note that ∣S11∣|S_{11}| in dB is the negative of the return loss shown here.

References

  1. P. H. Smith, "Transmission line calculator," Electronics, vol. 12, no. 1, pp. 29–31, Jan. 1939.
  2. D. M. Pozar, Microwave Engineering, 4th ed., Wiley, 2012, §2.3–2.5 (reflection, the Smith chart, the quarter-wave transformer) and §5.1–5.2 (L-section and single-stub matching).
  3. G. Gonzalez, Microwave Transistor Amplifiers: Analysis and Design, 2nd ed., Prentice Hall, 1997, §2.4–2.5 (the Smith chart and constant-Q contours).
  4. A. Arsenovic et al., "scikit-rf: An open-source Python package for microwave network creation, analysis, and calibration," IEEE Microwave Magazine, vol. 23, no. 1, pp. 98–105, Jan. 2022.

This calculator's results are checked against 32 independent reference values in automated tests on every change. How we check accuracy.