Skip to content
FiftyOhm
Esc
  • Air-core coilSingle-layer air-core solenoid inductance from Nagaoka's exact coefficient, compared with Wheeler's formula. Solve for the number of turns for a target inductance.Components & magnetics
  • Attenuator PadsResistor values for Pi, T, bridged-T and minimum-loss L-pad attenuators, with unequal impedances, power dissipation per resistor and E24/E96 rounding.Couplers, dividers & attenuators
  • CoaxCoax Z0, capacitance and inductance per length, velocity factor, loss, exact TE11 cutoff and breakdown voltage. Solve for D, d or εr from Z0.Transmission lines
  • CPW / GCPWCoplanar waveguide and grounded CPW impedance, effective permittivity, dispersion, delay and loss by conformal mapping. Solve for centre width or gap.Transmission lines
  • dBm ↔ W ↔ VConvert RF power between dBm, dBW, watts, Vrms, Vpeak, Vpp, dBµV and dBmV for any system impedance. Instant, accurate, with formulas.Fundamentals & conversions
  • Differential pairEdge-coupled microstrip and stripline differential impedance, Z0 even/odd, common-mode impedance, coupling and delay. Solve for spacing or width from Zdiff.Transmission lines
  • Filter OrderMinimum filter order to meet a passband/stopband attenuation mask for Butterworth, Chebyshev and elliptic responses, with the attenuation actually achieved.Filters
  • Free-space path lossFree-space path loss from the Friis equation, received power with antenna gains, and a far-field check. Solve for distance or frequency.Propagation & link budget
  • L / Pi / T MatchingDesign lumped L, Pi and T matching networks between complex source and load impedances. Both L solutions, loaded-Q Pi/T, component values and bandwidth.Matching & Smith chart
  • LC Filter DesignerDesign lumped LC ladder filters: Butterworth, Chebyshev or Bessel; low-pass, high-pass, band-pass, band-stop to order 10, with exact insertion loss and group delay.Filters
  • MicrostripMicrostrip Z0, effective permittivity, dispersion, delay and loss. Solve for trace width from target impedance. Hammerstad–Jensen + Kirschning–Jansen models.Transmission lines

Air Core Inductor Calculator (Single-Layer Coil)

Single-layer air-core solenoid inductance from Nagaoka's exact coefficient, compared with Wheeler's formula. Solve for the number of turns for a target inductance.

5 cited sources16 reference checksRuns in your browser

Inputs

Form diameter plus one wire diameter: the current-sheet diameter is measured between wire centres.

Turns × pitch (end to end of the winding, centre to centre plus one pitch).

Only used to check that the turns fit and to report the spacing ratio.

Results

Inductance (Nagaoka, exact current sheet)(L)
506.57
Inductance (Wheeler)(L_W)
504.74
Nagaoka coefficient(K_N)
0.769888
Wheeler − Nagaoka
−0.36%
Long-solenoid limit μ0N²A/ℓ
657.97
Turn pitch ℓ/N(p)
1.5
Pitch / wire diameter(p/d_w)
1.5
Wire length (winding only)
314.52
Length / diameter(ℓ/D)
1.5
  • Low-frequency current-sheet inductance. Round-wire (Rosa) corrections, typically ~1–3 %, are not applied. Close to self-resonance the apparent inductance rises; keep the operating frequency well below the coil's SRF.

Formulas

L=μ0 π(D/2)2N2ℓ KNL = \frac{\mu_0\,\pi (D/2)^2 N^2}{\ell}\,K_NKN=43πk′[(1−k2)K(k)−(1−2k2)E(k)k2−k],k=DD2+ℓ2K_N = \frac{4}{3\pi k'}\left[\frac{(1-k^2)K(k) - (1-2k^2)E(k)}{k^2} - k\right],\quad k = \frac{D}{\sqrt{D^2+\ell^2}}LW [μH]=a2N29a+10b(a=D/2, b=ℓ in inches)L_W\,[\mu\mathrm{H}] = \frac{a^2N^2}{9a + 10b}\quad (a = D/2,\ b = \ell\ \text{in inches})

What this calculator does

A single-layer air-core coil (a solenoid) is the simplest high-Q inductor for RF work. You find it in tank circuits, filters, matching networks and antenna loading coils. Its inductance depends only on geometry. This calculator computes it two ways:

  • Nagaoka's coefficient, computed exactly: the inductance of an ideal cylindrical current sheet of diameter DD and length ℓ\ell with NN turns;
  • Wheeler's formula (1928), the hand-calculation formula found in the ARRL Handbook, for comparison.

It also reports the long-solenoid limit, the turn pitch, the spacing relative to the wire diameter and the length of wire in the winding. Solve-for gives you the number of turns for a target inductance.

The current-sheet model and Nagaoka's coefficient

An infinitely long solenoid has L=μ0N2A/ℓL = \mu_0 N^2 A/\ell. A real coil has ends, where the field spreads out. The field inside is therefore weaker, and the inductance is lower, by Nagaoka's coefficient KNK_N, which depends only on the shape D/ℓD/\ell:

L=μ0 π(D/2)2N2ℓ KN.L = \frac{\mu_0\,\pi (D/2)^2 N^2}{\ell}\,K_N.

Nagaoka (1909) expressed KNK_N through complete elliptic integrals. With the modulus k=D/D2+ℓ2k = D/\sqrt{D^2+\ell^2} and k′=1−k2k' = \sqrt{1-k^2},

KN=43πk′[(1−k2)K(k)−(1−2k2)E(k)k2−k].K_N = \frac{4}{3\pi k'}\left[\frac{(1-k^2)K(k) - (1-2k^2)E(k)}{k^2} - k\right].

The calculator evaluates K(k)K(k), E(k)E(k) and the difference K−EK-E in a single arithmetic-geometric-mean (AGM) loop. That makes the result exact to double precision for any shape, from flat pancake-like coils to very long solenoids. Nagaoka's 1909 tables and Rosa and Grover's tables (1912) were the reference for a century, and these values agree with them.

Wheeler's formula

L [μH]=a2N29a+10bL\,[\mu\mathrm{H}] = \frac{a^2N^2}{9a + 10b}

with radius aa and length bb in inches. Wheeler claimed ±1 % for b>0.8ab > 0.8a, that is ℓ/D>0.4\ell/D > 0.4. In Nagaoka terms, it amounts to approximating KN≈1/(1+0.45 D/ℓ)K_N \approx 1/(1 + 0.45\,D/\ell). The calculator shows the percentage difference, so you can see where the approximation holds. For flat coils it degrades quickly.

How to use solve-for

Click ⇄ Solve next to Number of turns, choose Inductance (Nagaoka) as the target, and enter your inductance. The answer is usually fractional. Round it, then adjust the winding length (spacing) to trim, which is how coils are tuned in practice. You can also solve Winding length for a target inductance with a fixed number of turns, or Coil diameter to choose a form size.

Worked example

A coil wound on a former, with a 10 mm diameter between wire centres, 15 mm long, with 10 turns of 1 mm wire:

QuantityResult
Nagaoka coefficient KNK_N (ℓ/D=1.5\ell/D = 1.5)0.76989
Inductance, Nagaoka506.57 nH
Inductance, Wheeler504.74 nH (−0.36 %)
Long-solenoid limit (no end correction)657.97 nH
Pitch / wire diameter1.5

Ignoring the end effect would overestimate the inductance by 30 %, while Wheeler's formula is within 0.4 % at this shape. To reach 1 µH on the same form and length, solve for the turns: N=14.05N = 14.05.

The ARRL Handbook's own example of Wheeler's formula, 48 turns at 32 turns per inch on a ¾ in diameter (ℓ = 1.5 in), gives 17.6 µH, and the calculator's Wheeler output agrees.

Accuracy and validity

ModelAccuracyRange
Nagaoka (exact current sheet)Exact for a uniform current sheetAny D/ℓD/\ell
Wheeler (1928)±1 % claimed; typically better than 0.4 %ℓ/D>0.4\ell/D > 0.4

The current-sheet value is exact, but a real coil is not a current sheet:

  • Round wire and spacing. The current flows in discrete round wires, not in a continuous sheet. Rosa's corrections for this effect are typically 1–3 % for practical spacings. Their size and sign depend on the ratio of pitch to wire diameter. These corrections are not applied here.
  • Diameter definition. Use the diameter between wire centres. At RF the current crowds to the inside of the winding, which reduces the effective diameter slightly and lowers LL by up to a few percent for thick wire.
  • Frequency. The value is the low-frequency inductance. As the frequency approaches self-resonance, the coil's self-capacitance makes the apparent inductance rise. Keep the operating frequency well below the self-resonant frequency (SRF), preferably below SRF/3.

This calculator does not yet estimate self-capacitance, SRF or Q. Medhurst's (1947) measurements and the formulas fitted to them are the standard starting point, but confirm critical coils with a measurement.

Practical notes

  • Q is best near ℓ/D ≈ 1 and with a pitch of about two wire diameters. Spacing the turns lowers the proximity-effect loss and the self-capacitance.
  • Keep metal away. A shield or chassis closer than about one coil diameter lowers both L and Q. Mount coils at right angles to each other to minimise coupling.
  • Trim by spacing. Compressing the turns raises L and stretching them lowers it, which gives a few percent of fine adjustment without rewinding.
  • Leads count. Each centimetre of lead adds roughly 5–10 nH, which matters for coils of a few tens of nH.

References

  1. H. Nagaoka, “The Inductance Coefficients of Solenoids,” J. College of Science, Imperial University of Tokyo, vol. 27, art. 6, pp. 1–33, 1909.
  2. E. B. Rosa and F. W. Grover, “Formulas and Tables for the Calculation of Mutual and Self-Inductance,” Bulletin of the Bureau of Standards, vol. 8, no. 1, 1912 (Scientific Paper 169).
  3. H. A. Wheeler, “Simple Inductance Formulas for Radio Coils,” Proc. IRE, vol. 16, no. 10, pp. 1398–1400, Oct. 1928.
  4. R. Lundin, “A Handbook Formula for the Inductance of a Single-Layer Circular Coil,” Proc. IEEE, vol. 73, no. 9, pp. 1428–1429, Sept. 1985.
  5. D. W. Knight, “An Introduction to the Art of Solenoid Inductance Calculation,” v0.19, 2013, g3ynh.info (§7–8: Nagaoka's coefficient, Lundin and Wheeler formulas).

This calculator's results are checked against 16 independent reference values in automated tests on every change. How we check accuracy.